Ecological Archives A025-024-A1
Kyle G. Horton, W. Gregory Shriver, and Jeffrey J. Buler. 2015. A comparison of traffic estimates of nocturnal flying animals using radar, thermal imaging, and acoustic recording. Ecological Applications 25:390–401. http://dx.doi.org/10.1890/14-0279.1
Appendix A (Table A1). Raven Pro v1.4 band-limited energy detector parameters used for automated call detection.
Parameter |
Low frequency detector |
High frequency detector |
Flight Call Signal Parameters |
||
Minimum Frequency (Hz) |
2500 |
6500 |
Maximum Frequency (Hz) |
5500 |
8000 |
Minimum Duration (s) |
29.0294 |
17.41497 |
Maximum Duration (s) |
446.98413 |
597.91383 |
Minimum Separation (s) |
249.61451 |
17.41497 |
Signal-to-noise Ratio Parameters |
||
Minimum Occupancy (%) |
20 |
60 |
Single-to-noise Threshold (dB) |
5 |
6.5 |
Block Size (s) |
9996.19048 |
9990.38549 |
Hop Size (s) |
249.61451 |
249.61451 |
Percentile |
30 |
65.0 |